R
 
Home Ueber uns Internet Kontakt Links Partner News Demo & Occ Angebote Support        
  Pneumologie
Lungenfunktion
  Ergospirometrie
ger   Nutrition
  portable Spirometrie
  Filter
  Gefässdiagnostik
  Vicorder
  Pocket Doppler
  TCD-Doppler
  VaSera
  AngE Angio Experience
  Occ Ultraschallgeräte
  EKG
frferg   EKG - Windows
dgfr   EKG portabel
  Med Diagnostik Worksation
  Med Diagnostik Worksation
  Blutdruckmessung
  Suntech 24 Std ABD
a   Stress BD Tango
a   Sress BD Cycle
a   Suntech BP/Temp/SpO2
a   Manschetten
 
  Fahrrad Ergometer Lode
  Corival
  Corival Recument
  Corival Pediatric
  Excalibur Sport
EKG   Nuclear Corival
  Laufband Lode
Diagnostik   Valiant
  Lode Imaging Ergometer
  Imaging Ergometrie
  Lode Special Ergometer
a   Aristokin
a   Handdruck Dynamometer
a   Fingerdruck Dynamometer
a   Exzentrische Ergometer
a   Lode Ergometrie Manager
  wIRA Wärmetherapie
  wIRA Einführung
a   wIRA Hydrosun
a   Wundheilung
a   Rheuma/Arthrose
  Warzenbehandlung
  Hals/Nasen/Ohren
Cycle


Focus on your patient's performance by using automated BP in bicycle cardiac stress testing.

Specifically designed for use in bicycle ergometer cardiac stress testing, the Cycle™ Monitor reliably monitors BP allowing you to focus on your patients. The new Cycle™ stress BP monitor is ideal for an ergometric stress lab where tolerance to exercise is key. When reliable automatic BP is required, SunTech Medical delivers. Add the SpO2 measurement option to make your stress ECG system a complete and seamless
diagnostic test center.

SunTech's proprietary algorithms provide uniquely exceptional performance in a difficult environment, and along with the hands-free interface make Cycle™ an indispensable part of stress testing.

Features and Benefits

Reliably monitor patients

  • Motion Tolerant Performance: Cycle™ measures BP in high motion clinical applications where standard BP monitors simply do not work. Proprietary SunTech algorithms report clinically reliable, accurate measurements.
  • Stat mode: Systolic BP's in as little as 15 seconds and full BP's in 30 seconds for time sensitive or emergency situations.

Access patients' vital signs quickly and easily

  • Interfaced with your stress ECG system, Cycle transfers BP data to your system's display and reports.
  • Ideal for use on stress systems without an ECG trigger
  • Easy to read display showing BP, heart rate, and SPO2 (optional)
  • Optional Headphone option allows for monitoring of the K-sounds

Conduct stress tests reliably and quickly with the specially designed Orbit-K cuff

  • Cycle and Orbit-K simplify patient preparation
  • Cuff stays in position even during exercise
  • Comfortable for patients
  • Easy to use for clinicians

Customize your monitor for your needs

  • Use the Cycle with or without a compatible stress system; take readings at user defined intervals of 1 ½, 2, 3, 4 or 5 minutes
  • Define the maximum inflation pressures and deflation rates
  • Ideal for research and clinical activities where comparison to trained observers is required

Product Specifications

BP Measurement: Auscultatory method for use during all static and active phases of ergometric stress testing.

Measurement Range: Systolic- 50-250 mmHg, Diastolic- 20-150 mmHg,
Heart rate- 40-200 bpm

Accuracy: Equivalent to a trained observer using the cuff/stethoscope auscultation method per ANSI/AAMI SP10:2002

Interfaces: Integrates with all popular stress ECG systems using RS-232.

Classification: Class II, Continuous operation

Warranty: 2 year standard warranty

Weight: 0.5 kg (17.9 oz)

Calibration: Verify the accuracy of cuff pressure transducers/ indicators annually.

Sampling Intervals: From integrated stress ECG system or other external source, or 1.5, 2, 3, 4, 5 min, intervals.

Power: Input- 100-240 VAC @50-60 Hz, Output - 9 VDC @5 A

Dimensions: 12.0 cm x 6.3 cm x 15.0 cm, (4.7"x5.9"x2.5")

Standards: IEC 60601-1, IEC 60601-2-30, ISO 9919, IEC 60601-1-2 (EMC), EN 1060-1, EN 1060-3, UL 60601-1, CAN/CSA 22.2 601-1

Cycle Interface Information

You can set up the Cycle to work directly with your stress system. This means your stress system can prompt the Cycle to take a BP measurement while you are performing a stress test. In addition, on some systems, the measurement from the Cycle will be transferred to your stress system to be displayed on screen and printed on any reports.